commercial Inspections
  • Features
  • Specifications
Thermal Cameras for Automation

FLIR A300 & A310 Features

FLIR A300 Features

  • MPEG-4 streaming
  • PoE (Power over Ethernet)
  • Built-in web server
  • General purpose I/O
  • 100 Mbps Ethernet (100 m cable, wireless, fiber, etc.)
  • Synchronization through SNTP
  • Composite video output
  • Multi-camera utility software: FLIR IP Config and FLIR IR Monitor included
  • Open and well-described TCP/IP protocol for control and set-up
  • 16-bit 320 × 240 images @ 3 Hz, radiometric
  • Lenses: 25° included, 15° and 45° optional

 

FLIR A310 Features

  • Support for EthernetIP field bus protocol (analyse, alarm, and simple camera control)
  • Support for Modbus TCP field bus protocol (analyse, alarm, and simple camera control)
  • Built-in extensive analysis functionality
  • Extensive alarm functionality, as a function of analysis and more
  • On schedule: file sending (FTP) or email (SMTP) of analysis results or images
  • On alarms: file sending (FTP) or email (SMTP) of analysis results or images
  • MPEG-4 streaming
  • PoE (Power over Ethernet)
  • Built-in web server
  • General purpose I/O
  • 100 Mbps Ethernet (100 m cable, wireless, fiber, etc.)
  • Synchronization through SNTP
  • Composite video output
  • Multi-camera utility software: FLIR IP Config and FLIR IR Monitor included
  • Open and well-described TCP/IP protocol for control and set-up
  • 16-bit 320 × 240 images @ 7–8 Hz, radiometric
  • Lenses: 25° included, 15° and 45° optional
Thermal Cameras for Automation

FLIR A300/A310 Specifications

Model Number FLIR A300 FLIR A310
  A300 A310

Imaging & Optical Data

Field of View (FOV) / Minimum Focus Distance 25° × 18.8° / 0.4 m
Lens Identification Automatic
Thermal Sensitivity < 0.05°C at +30°C / 50 mK
Foucs Automatic or manual
F-Number 1.3
Image Frequency - NTSC & MPEG4 30 Hz
Lens Options Standard: 25° × 19°; Optional: 90°, 45°, 15°, 6°
Zoom 1–8× continuous, digital, interpolating zooming on images

Detector Data

IR Resolution 320 × 240 pixels
Detector Pitch 25 μm
Detector Time Constant Typical 12 ms
Focal Plane Array (FPA) / Spectral Range Uncooled Microbolometer / 7.5–13 μm

Measurement Analysis

Object Temperature Range –20 to +120°C
0 to +350°C
High Temp Option Up to 3,632°F (2,000°C)
Accuracy ±2°C or ±2% of reading
Spotmeter N/A 10
Area N/A 10 boxes with max./min./average/position
Isotherm N/A 1 with above/below/interval
Measurement Option N/A Measurement Mask Filter Schedule response: File sending (ftp), email (SMTP)
Difference Temperature N/A Delta temperature between measurement functions or reference temperature
Reference Temperature N/A Manually set or captured from any measurement function
Atmospheric Transmission Correction N/A Automatic, based on inputs for distance, atmospheric temperature and relative humidity
Optics Transmission Correction N/A Automatic, based on signals from internal sensors
Emissivity Correction N/A Variable from 0.01 to 1.0
Reflected Apparent Temperature Correction N/A Automatic, based on input of reflected temperature
External Optics/Windows Correction N/A Automatic, based on input of optics/window transmission and temperature
Measurement Corrections N/A Global and individual object parameters

Alarm

Alarm Functions N/A 6 automatic alarms on any selected measurement function, Digital In, Camera temperature, timer
Alarm Output N/A Digital Out, log, store image, file sending (ftp), email (SMTP), notification

Set-Up

Color Palettes Color palettes (BW, BW inv, Iron, Rain)
Set-up Commands Date/time, Temperature°C

Storage of Images

Image Storage Types Built-in memory for image storage
File Formats Standard JPEG, 16-bit measurement data included

Composite Video

Video Composite video output, PAL and NTSC compatible
Video, Standard CVBS (ITU-R-BT.470 PAL/SMPTE 170M NTSC)

Digital Input/Output

Digital Input 2 opto-isolated, 10–30 VDC
Digital Output, Purpose As function of ALARM, Output to ext. device (programmatically set)
Digital Output 2 opto-isolated, 10–30 VDC, max 100 mA
Digital I/O, Isolation Voltage 500 VRMS
Digital I/O, Supply Voltage 12/24 VDC, max 200 mA
Digital I/O, Connector Type 6-pole jackable screw terminal
Digital Input, Purpose Image tag (start/stop/general), Input ext. device (programmatically read)

Ethernet

Ethernet Control and image Control, result and image
Ethernet, Protocols TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP Ethernet/IP, Modbus TCP, TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP
Ethernet, Image Streaming 16-bit 320 x 240 pixels at 3 Hz
- Radiometric
16-bit 320 x 240 pixels at 7-8 Hz
- Radiometric
Ethernet, Type 100 Mbps
Ethernet, Standard IEEE 802.3
Ethernet, Connector Type RJ-45
Ethernet, Type 100 Mbps
Ethernet, Communication TCP/IP socket-based FLIR proprietary
Ethernet, Video Streaming MPEG-4, ISO/IEC 14496-1 MPEG-4 ASP@L5
Ethernet, Power Power over Ethernet, PoE IEEE 802.3af class 0

Power System

External Power Operation 12/24 VDC, 24 W absolute max
External Power, Connector Type 2-pole jackable screw terminal
Voltage Allowed range 10–30 VDC

Environmental Data

Operating Temperature Range 5°F to 122°F (-15°C to 50°C)
Storage Temperature Range -40°F to 158°F (-40°C to 70°C)
Humidity (operating and storage) IEC 60068-2-30/24 h 95% relative humidity +25°C to +40°C
EMC EN 61000-6-2:2001 (Immunity)
EN 61000-6-3:2001 (Emission)
FCC 47 CFR Part 15 Class B (Emission)
Vibration / Bump 2 g (IEC 60068-2-6) / 25 g (IEC 60068-2-29)
Encapsulation IP 40 (IEC 60529)

Physical Data

Housing Material Aluminium
Camera Size (L × W × H) 170 × 70 × 70 mm
Weight 0.7 kg
Tripod Mounting UNC ¼"-20 (on three sides)
Base Mounting 2 × M4 thread mounting holes (on three sides)
Commercial Inspections